  SICK CDF600-2200(1062460)

  The CDF600-2200 fieldbus module is used exclusively to integrate a single identification sensor as an IO device in PROFINET IO networks. It provides a dual port switch for the fieldbus for the assembly of e. g. a line topology. In terms of data technology, the fieldbus module and identification sensor (referred to as the ID sensor below) represent an IO device (field device) on the bus; they communicate with one another via a serial data interface (RS-232). One fieldbus module is required for each ID sensor on the PROFINET IO network.

CDF600-2200.png

  The CDF600-2200 fieldbus module currently supports the following ID sensors:

  In proxy mode:

  • CLV61x FIELDBUS, CLV62x ... 65x and CLV69x bar code scanners

  • Lector®62x image-based code reader

  • RFH62x ... 63x (HF), RFU63x (UHF) RFID interrogators

  In gateway mode:

  • IDM16x hand-held scanners

  • Any sensor with RS-232 interface and suitable data format and data transmission rate.

  The fieldbus module can be used at an ambient temperature range of –35 °C to + 50 °C. Correct use also includes compliance with all information in these operating instructions and the supplementary & "CDF600-2200 Fieldbus module" Technical Information (no. 8015924).

  About this document

  These operating instructions will help you to assemble a CDF600-2200 fieldbus module in the ambient temperature range from 0 °C to +50 °C quickly and easily and establish an electrical connection between it and the ID sensor, fieldbus and local trigger sensor (if required). The operating mode of the fieldbus module is set via its mechanical control element.

  The CDF600-2200 fieldbus module is referred to in the following sections simply as “fieldbus module”.

  Supplementary and applicable documents

  More detailed information about the electrical installation and configuration of the fieldbus module is available in the & “CDF600-2200 fieldbus module” Technical Information (no. 8015924). This document describes:

  • The suppression of ground potential equalization currents in applications with distributed systems

  • The use of the fieldbus module together with a heatable ID sensor that supports proxy mode in the deep-freeze range up to –35 °C

  • Setting up a small SICK CAN sensor network as a subnetwork on the ID-Sensor connected to the fieldbus module

  • Integration of the fieldbus module in the IO controller

  • The procedure for configuring the fieldbus module with the SOPAS ET configuration software of the ID sensor supporting proxy mode or through the IO controller with the help of modules from the GSDML file

  • The connection and configuration of the hand-held scanner by means of controlled scanning of the corresponding bar codes

  Information about PROFINET IO-related configuration is also available in the online help for the relevant proxy ID sensor.