MTL7742
MTL7742 proximity sensor or switch input with solid state output The MTL7742 is a single channel switch/prox input barrier with an open collector solid state interface to the safe area equipment. The solid state switch is especially...
-
MTL7741
MTL7741 proximity sensor or switch input and relay output The MTL7741 is a single channel switch/prox input barrier with changeover relay contacts acting as the safe area interface. Relay contacts provide a universal interface capable...
-
MTL7707P+
MTL7707P+ for switch inputs and switched outputs, 2W Transmitters (IIB gases) The MTL7707P+ is a two-channel shunt-diode safety barrier similar to the MTL7787P+, but is designed for use with group IIB gases and features built-in ele...
-
MTL7707+
MTL7707+ for switch inputs and switched outputs The MTL7707+ is a 2-channel shunt-diode safety barrier similar to the MTL7787+ but with built-in electronic overvolt protection. It is intended primarily for safeguarding a hazardous-ar...
-
MTL7706+
The MTL7706+ is a 1-channel shunt-diode safety barrier, with builtin electronic overvolt protection, for energising a 2-wire, 4/20mA transmitter in a hazardous area. It is powered from a positive supply of 20–35V dc and delivers a...
-
MTL7755AC
MTL7755AC barriers protect devices located in all normally occurring explosive atmospheres, including air/flammable gas mixtures, dusts and fibres. Applications covered include the protection of installations incorporating uncertifi...
-
MTL7755AC/7758+/7758-/7761ac/7761Pac
The MTL7758+,MTL,MTL7755AC,MTL7758-,MTL7761ac,MTL7761Pac range, with their advanced features, should be regarded as your first choice for all new designs or installations. The recommendations below are based therefore on the MTL7700 r...
-
MTL5553
The MTL5553 has been specifically developed to extend 31.25kbit/s (H1) fieldbus networks into hazardous areas. It provides power and communication to devices powered through the signal conductors. For installations in which the safe...
-
PCL45USB/PCS45
1 INTRODUCTION The PCS45/PCL45USB configurator enables Eaton’s MTL temperature converters and pulse isolators, part of Crouse-Hinds series, to be configured from a standard PC running a Microsoft® Windows® operating system. The confi...
-
MTL5546Y-T
The MTL5546Y-T accepts a 4/20mA floating signal from a safe-area controller to drive a current/pressure converter (or any other load up to 800Ω) in a hazardous area. For HART valve positioners, the module also permits bi-directional...