微信
二维码
18070781367@163.com WhatsApp:+86 18278761660
2024年07月26日 gyp12345 Mtl 84 0

   in stocks

  Quantity: 33pcs

  Price: US$ 245

  The MTL4531/MTL5531 repeats a signal from a vibration sensor in a hazardous area, providing an output for a monitoring system in the safe area. The interface is compatible with 3-wire eddy-current probes and accelerometers or 2-wire current sensors; the selection is made by a switch on the side of the module.

image.png

  SPECIFICATION

  See also common specification

  Number of channels

  One

  Sensor type

  2- or 3-wire vibration transducer

  Location of signal source

  Zone 0, IIC, T4–6 hazardous area if suitably certified

  Div. 1, Group A hazardous location

  Hazardous-area

  input Input impedance

  (terminals 2 & 3): 10kΩ

  Transducer supply current, 2-wire

  3.3mA (nom.) for 2-wire sensors, user selectable by switch

  Signal range

  Minimum –20V, maximum –0.5V

  DC transfer accuracy at 20°C

  <±50mV

  AC transfer accuracy at 20°C

  0Hz to 1kHz: ±1%

  1kHz to 10kHz: –5% to +1%

  10kHz to 20kHz: –10% to +1%

  Temperature coefficient

  ±50ppm/°C (10 to 65°C)

  ±100ppm/°C (–20 to 10°C)

  Voltage bandwidth

  –3dB at 47kHz (typical)

  Phase response

  <14µs, equivalent to:

  –1° at 200Hz

  –3° at 600Hz

  –5° at 1kHz

  –50° at 10kHz

  –100° at 20kHz

  Safe-area output impedance

  <20Ω

  LED indicator

  Green: power indication

  Supply voltage

  20 to 35V dc

  Maximum current consumption (10mA transducer load)

  65mA at 24V

  Maximum power dissipation within unit 1.33W

  Safety description

  Terminals 3 to 1

  Uo=26.6V Io=94mA Po=0.66W Um = 253V rms or dc

  Terminals 3 to 2

  Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW


评论